TITAN AI · CONDUIT Agent

CONDUIT TICKET REPORT

CHG0030105
TICKET
🖨 Print / Save as PDF ⬇ PDF ⬇ DOCX
TICKET AWS High Assigned
Opened by TITAN AI · CONDUIT · Scanner found the finding, CONDUIT forwarded this ticket via CONDUIT generic-API layer, assigned network_operations, populated every ticket field, The ticket is routed and awaiting team approval — CONDUIT will update it after TITAN FORGE applies the fix.

Finding Summary

Short description
[TITAN] High — network on sg-banking-webtier-prod
Severity
High
Priority
2 - High
Resource
sg-banking-webtier-prod
Resource type
AWS::EC2::SecurityGroup
Cloud
AWS
Subscription / Account
4503-6703-8821
Resource group / Project
banking-prod

The Security Finding

Security group sg-banking-webtier-prod allows 0.0.0.0/0 on port 3306 (MySQL) — production banking DB exposed to internet. PCI DSS 1.2.1 firewall/router configuration violation.

ITIL Change Management Fields

Justification

High: Security group sg-banking-webtier-prod allows 0.0.0.0/0 on port 3306 (MySQL) — production banking DB exposed to internet. PCI DSS 1.2.1 firewall/router configuration violation.

Implementation Plan

1. Pre-change snapshot captured by TITAN (auto-rollback available).
2. Execute fix command:
   aws ec2 revoke-security-group-ingress --group-id sg-0abc123 --protocol tcp --port 3306 --cidr 0.0.0.0/0
3. TITAN FORGE verifies the fix was applied.
4. Post-change rescan by TITAN SCOUT — finding must no longer appear.
5. Close ticket with Successful close_code.

Risk & Impact Analysis

Risk level: MEDIUM-HIGH risk — misconfiguration with realistic exploit path.
Business impact if unremediated: Increases attack surface; auditor finding likely.
Scope: single resource (sg-banking-webtier-prod).
Blast radius: change is idempotent; pre-change snapshot captured by TITAN; auto-rollback available if rescan fails.
Finding detail: Security group sg-banking-webtier-prod allows 0.0.0.0/0 on port 3306 (MySQL) — production banking DB exposed to internet. PCI DSS 1.2.1 firewall/router configuration violation.

Backout / Rollback Plan

1. TITAN auto-captured snapshot of sg-banking-webtier-prod before change (baseline: titan-banking-demo-20260422T201922Z).
2. If post-change rescan still shows the finding OR a new issue appears within 15 min:
   a. TITAN FORGE fires rollback automatically using stored snapshot.
   b. Incident reopens and escalates to on-call.
3. Manual rollback command path (human override) is documented in close notes.

Test Plan

1. TITAN SCOUT rescans sg-banking-webtier-prod immediately after FORGE applies the change.
2. PASS criteria: the specific finding no longer appears in SCOUT results.
3. PASS criteria: no new CRITICAL or HIGH findings introduced by the change.
4. Automated compliance check: HIPAA/PCI/SOC2 controls re-evaluated.
5. If any check fails, backout plan fires automatically.

Recommended Fix

aws ec2 revoke-security-group-ingress --group-id sg-0abc123 --protocol tcp --port 3306 --cidr 0.0.0.0/0

Compliance Mapping

CIS Azure 6.2NIST SC-7PCI DSS 1.2.1

Routing Metadata

Assignment group
network_operations
Change type
Normal
Approval required
Yes
Planned start
2026-04-22 20:03:22
Planned end
2026-04-22 22:03:22
Scan ID
titan-banking-demo-20260422T201922Z
Generated at
2026-04-22T19:49:22+00:00
Opened
2026-04-22 19:49:22
Closed
2026-04-22 19:49:22
Close code

Attached Security Ticket

SERVICENOW · TICKET
SEC-6139 · [TITAN] High — network on sg-banking-webtier-prod
Priority: High TICKET AWS

Ticket Description

Security group sg-banking-webtier-prod allows 0.0.0.0/0 on port 3306 (MySQL) — production banking DB exposed to internet. PCI DSS 1.2.1 firewall/router configuration violation.

Recommended Fix: aws ec2 revoke-security-group-ingress --group-id sg-0abc123 --protocol tcp --port 3306 --cidr 0.0.0.0/0

AI Close Notes

TITAN CONDUIT opened this high network ticket and assigned it to the banking_compliance group for review. STATE: ASSIGNED — awaiting human action. Per TITAN AI policy, configuration changes are NEVER auto-applied and tickets are NEVER auto-closed by TITAN. The assigned group reviews the recommended fix, schedules an approved maintenance window, applies the fix manually, validates via SCOUT rescan, and closes this ticket themselves. TITAN documents and routes — the human owns the change from here.